PBS-70

Pulverised Magnetite Ore

PBS-70 is a certified reference material (CRM) derived from pulverized magnetite ore sourced from a Western Australian mine. Certified in accordance with ISO Guide 35, PBS-70 is designed for rigorous quality control and validation of methods in geochemical and metallurgical laboratories performing XRF fusion, Davis Tube Recovery (DTR), Loss on Ignition (LOI), and Particle Size Distribution (PSD) measurements.

Key Features

  • Certified concentrations for major, minor, and trace elements in both head sample and Davis Tube magnetic concentrate.
  • Manufactured through a multi-stage process involving drying, crushing, milling, and homogenization to ensure excellent homogeneity.
  • Certified via a multi-laboratory round robin involving 8 laboratories across Australia, with statistical validation of results.
  • Supplied in 1kg press-sealed plastic jars, with 10g sachets available upon request for blind laboratory submissions.
  • Stable under standard storage conditions, with recommended drying at 105°C prior to use for accurate results.

Key Values

Head of CRM (via Fusion XRF, % w/w)

Analyte

unit

Value

Standard Deviation

95% Conf. Int.

1 SD

1 SD Within Lab

lower

upper

Fe

%

30.46

0.100

0.071

30.37

30.54

SiO2

%

47.54

0.122

0.111

47.46

47.61

Al2O3

%

1.49

0.017

0.010

1.48

1.51

TiO2

%

0.073

0.0038

0.0033

0.071

0.075

Mn

%

0.117

0.0035

0.0023

0.115

0.120

CaO

%

0.492

0.0071

0.0052

0.487

0.497

P

%

0.102

0.0019

0.0009

0.101

0.104

S

%

0.133

0.0017

0.0013

0.132

0.135

MgO

%

2.260

0.0240

0.0110

2.240

2.280

K2O

%

0.675

0.0115

0.0050

0.664

0.685

Na2O

%

0.149

0.0140

0.0060

0.136

0.162

LOI 1000

%

3.28

0.097

0.041

3.19

3.37

Davis Tube Magnetite Concentrate (via Fusion XRF, % w/w)

Analyte

unit

Value

Standard Deviation

95% Conf. Int.

1 SD

1 SD Within Lab

lower

upper

Fe

%

62.01

1.030

0.364

61.15

62.87

SiO2

%

11.77

1.053

0.323

10.88

12.66

Al2O3

%

0.31

0.041

0.016

0.28

0.35

TiO2

%

0.030

0.0056

0.0030

0.026

0.035

CaO

%

0.155

0.0153

0.0067

0.143

0.168

MgO

%

0.512

0.0547

0.0181

0.466

0.558

K2O

%

0.132

0.0228

0.0076

0.113

0.151

P

%

0.039

0.0031

0.0012

0.037

0.042

LOI 1000

%

-1.70

0.168

0.095

-1.82

-1.57

Additional Parameters 

  • DTW Mass Recovery: 33.96% ± 1.273%

Intended Use

  • Monitoring and calibration of XRF fusion for iron ore and magnetite analysis.
  • Validation of Davis Tube Recovery (DTR) and mass yield calculations.
  • Calibration and validation of PSD measurements via laser diffraction and wet sieve methods.
  • Quality assurance for geochemical and metallurgical testing laboratories.

Pulverised Magnetite

SKU: 10070

Downloads

CERTIFICATE

This product is out of stock.

Alternate Packing Options

CONTACT US
Share